Understanding and Troubleshooting Common Error Codes
This guide provides a detailed list of fault codes for the Creality K1 3D Printer, along with explanations and potential solutions. Each error code helps identify specific issues such as anomalies during printing, sensor failures, and connection problems, allowing users to troubleshoot effectively. By understanding these codes, users can ensure optimal printer performance and address any malfunctions promptly.
Here is a readable list of fault codes for the Creality K1 3D Printer:
1. **Error Code 100**: Issue copying Gcode from USB.
2. **Error Code 101**: AI detected anomaly during printing.
3. **Error Code 102**: Gcode file name too long.
4. **Error Code 103**: First layer detection abnormal.
5. **Error Code 104**: Heated bed foreign object detection.
6. **Error Code 105**: Laser radar sensor abnormal.
7. **Error Code 106**: Laser radar calibration failed.
8. **Error Code 107**: Flow detection failed.
9. **Error Code 108**: Laser radar offset correction failed.
10. **Error Code 109**: Throat fan abnormal.
11. **Error Code 110**: Main MCU connection abnormal.
12. **Error Code 111**: Nozzle MCU connection abnormal.
13. **Error Code 112**: Heated bed MCU connection abnormal.
14. **Error Code 500**: AI detected anomaly, only a prompt.
15. **Error Code 501**: Throat fan abnormal.
16. **Error Code 502**: Mainboard fan abnormal.
17. **Error Code 503**: First layer detection abnormal, only a prompt.
18. **Error Code 504**: Heated bed foreign object detection, only a prompt.
19. **Error Code 505**: Laser radar does not exist, only a prompt.
20. **Error Code 506**: Laser radar calibration failed, only a prompt.
21. **Error Code 507**: Laser radar calibration failed, only a prompt.
22. **Error Code 2000**: Unable to update MCU configuration.
23. **Error Code 2001**: Unknown exception.
24. **Error Code 2002**: Host cannot connect.
25. **Error Code 2014**: Slicing distance issue.
26. **Error Code 2016**: Print not paused, resuming aborted.
27. **Error Code 2019**: Target temperature out of range.
28. **Error Code 2020**: Homing error.
29. **Error Code 2021**: Homing timeout error.
30. **Error Code 2056**: Axis accelerometer data missing.
31. **Error Code 2060**: Unplug nozzle terminal.
32. **Error Code 2065**: Failed to set ADXL345 register.
33. **Error Code 2069**: M107 P3 code in slicing file.
34. **Error Code 2090**: Timer shut down, host overload.
35. **Error Code 2091**: Intermittent communication failure.
36. **Error Code 2092**: ADC out of range.
37. **Error Code 2093**: Microcontroller step rate issue.
38. **Error Code 2095**: Must return to origin first.
39. **Error Code 2111**: Extrusion below minimum temperature.
40. **Error Code 2112**: Movement exceeds extrusion amount.
41. **Error Code 2119**: Invalid ADXL345 ID.
42. **Error Code 2210**: Unable to auto-load filament.
43. **Error Code 2211**: Print paused.
44. **Error Code 2242**: First home error.
45. **Error Code 2243**: Out of range error.
46. **Error Code 2252**: Minimum parameter value error.
47. **Error Code 2253**: Maximum parameter value error.
48. **Error Code 2283**: Printer not prepared.
49. **Error Code 2295**: Attempt to restart MCU failed.
50. **Error Code 2298**: Unable to update MCU configuration.
51. **Error Code 2299**: Unable to configure MCU.
52. **Error Code 2300**: Error during MCU configuration.
53. **Error Code 2308**: Axis accelerometer data missing.
54. **Error Code 2313**: Internal accelerometer data error.
55. **Error Code 2340**: Heater temperature out of range.
56. **Error Code 2343**: Main MCU connection timeout.
57. **Error Code 2344**: Nozzle MCU connection timeout.
58. **Error Code 2345**: Heated bed MCU connection timeout.
59. **Error Code 2503**: Unable to read Z-axis stress data.
60. **Error Code 2504**: Z homing abnormal.
61. **Error Code 2505**: Motor drive chip TMC abnormal.
62. **Error Code 2506**: Communication abnormal.
63. **Error Code 2507**: Not heating as expected.
64. **Error Code 2510**: Heated bed thermistor abnormal.
65. **Error Code 2511**: Chamber temperature abnormal.
66. **Error Code 2512**: Main MCU chip temperature abnormal.
67. **Error Code 2513**: Command format incorrect.
68. **Error Code 2514**: Command parameter format incorrect.
69. **Error Code 2520**: Reading pressure sensor timeout.
70. **Error Code 2521**: Constant pressure data read.
71. **Error Code 2522**: Pressure sensor detection failure.
72. **Error Code 2523**: Measurement data loss.
73. **Error Code 2524**: High noise from pressure data.
74. **Error Code 2525**: Nozzle scraping heated bed.
75. **Error Code 2526**: Z-axis motor step loss.
76. **Error Code 2527**: Incomplete motor step data.
77. **Error Code 2528**: Configuration file fade_start too small.
Here are the remaining fault codes for the Creality K1 3D Printer:
78. **Error Code 2532**: Invalid motion system state.
79. **Error Code 2533**: Kinematic Error.
80. **Error Code 2540**: Nozzle thermistor short circuit.
81. **Error Code 2541**: Heated bed thermistor short circuit.
82. **Error Code 2542**: Nozzle temperature abnormal.
83. **Error Code 2543**: Heated bed temperature abnormal.
84. **Error Code 2544**: Printer not moving.
85. **Error Code 2545**: Kinematic error detected during print.
86. **Error Code 2546**: Motion planning error.
For further details and troubleshooting steps, visit the Creality K1 Fault Codes List.